NDT TypeFluorescent Penetrant Testing
Penetrant TypeType 1
Fluorescent Penetrant SensitivityLevel 1 - Low Sensitivity
Penetrant MethodsMethod A, Method C
Removal TypeWater Washable
Required EquipmentUV light source
Ideal ApplicationCastings, Engine cylinder blocks, Forgings, Pistons, Power train components, Rocker arms, Rough surface finish, Steering knuckles, Unmachined parts
Defect ExamplesCold shuts, Cracks, Delamination, Laps, Porosity, Seams
StandardsAECL, ASME BPVC, ASTM E1417, ASTM E2297, Boeing BAC 5423 PSD 6-46 or 8-4, Boeing PS-21202, General Electric P50YP107